1. Residual Chlorine Analyzers |
|
Series RAH-210 Simple to operate
Reagentless models available
pH Electrode
Gravity Reagent Feed
Convenient to maintain
Designed to handle harsh environments
Ideal for a variety of applications
Multiple turbidity ranges available
Adjustable high reading alarm
Optional integral data logger
RS484 MODBUS communication
NEMA4X (IP66) rated controller
100-250 VAC (50-60 Hz)
1 Amp, 24 Watts max.
|
Catalogue |
Series RAH-210
pH Electrode
|
Series RAH-210
Dual Gravity Reagent Feeder
|
|
|
Series RPH-250
Amperometric Probe-type Residual Analyzer
Reagentless
Probe-type residual measurement of:
Free Chlorine
Total Chlorine
Chlorine Dioxide
Chlorite
Ozone
Hydrogen Peroxide
Peracetic Acid
Bromine
Transparent flow cell
Gravity flow cell with bubble trap for most applications
Pressurized flow cell for probes with self cleaning
Allows Simple Calibration & Maintenance
Available Range (Free Cl2): 0-0.5, 0-2, 0-5, 0-10, 0-20, & 0-200 PPM
Available Range (Total Cl2): 0-0.5, 0-2, 0-5, 0-10, 0-20 PPM
Included Standard:
Four (4) programmable 4-20 mA outputs
Modbus communication (RS485)
Four (4) programmable alarm relays
Complete P&ID control program
Automatic pH compensation software
Options:
pH probe
Data logger
Sample water PRV with 0-15 PSI pressure gauge
NEMA4X (IP66) rated controller
100-250 VAC (50-60 Hz)
1 Amp, 24 Watts max.
Profibus communication can optionally be supported |
Catalogue
|
|
|
Data Logger
The RAH-DL1S data logger is an electronic device that automatically collects and records data over a period of time from the Hydro Instruments Residual Chlorine Analyzers.
The data logger utilizes an internal flash memory card for data storage and is programmable as to how often data from the attached residual analyzer is captured and stored. This allows for a comprehensive look of the sample water conditions being monitored over time similar to that of a circular chart recorder. |
Catalogue
|
|
|
Sample Water Recovery System
Eliminates wasted water from analytical devices.
Accomodates up to 20 gal / hour of sample water flow.
Provides safety / overflow connection and tubing.
Provides atmospheric pressure manifold to prevent suction being drawn on analysis instrument / device. |
Catalogue
|
|
|
PRV and Pressure Gauge Assembly
for Residual Chlorine Analyzers |
|
|
3. Gas Alarm Leak Detectors |
|
Series GA-180
H2S Gas Detector
Chlorine Gas Detector (Cl2)
Ammonia Gas Detector (NH3)
Up to 16 sensors in any combination
Scanning display of all sensor readings
Up to 35 relays ? user adjustable, latching & non-latching, failsafe & non-failsafe
Two common alarm relays
Integral 95 dB horn
Isolated 4-20mA outputs
MODBUS communication (RS485)
Profibus communication can optionally be supported
Optional internal data logger
Optional battery backup
Optional temperature monitoring
Modular circuitry
Password protected setup
NEMA4X (IP66) rated controller
100-250 VAC (50-60 Hz)
1 Amp, 24 Watts max. |
Catalogue
|
|
|
Series GA-171
Up to two sensors in any combination
Back lit LCD display-2 line, 20 characters per line
Simple keypad operation
User friendly calibration and operation
Chlorine gas detector, H2S gas detector, Ammonia gas detector, Sulfur Dioxide gas detector, and Hydrogen gas detector
Two programmable alarm relays
Latching/non-latching relay option
Danger/Warning LED?s built-in
4-20 mA output standard
MODBUS (RS-485) communication
Profibus communication can optionally be supported
NEMA4X (IP66) rated controller
100-250 VAC (50-60 Hz)
1 Amp, 24 Watts max |
Catalogue
|
|
|
Series GA-170 (Obsolete)
H2S Gas Detector
Chlorine Gas Detector (Cl2)
Ammonia Gas Detector (NH3)
Up to 16 sensors in any combination
Scanning display of all sensor readings
Up to 35 relays ? user adjustable, latching & non-latching, failsafe & non-failsafe
Two common alarm relays
Integral 95 dB horn
Isolated 4-20mA outputs
MODBUS communication (RS485)
Profibus communication can optionally be supported
Optional internal data logger
Optional battery backup
Optional temperature monitoring
Modular circuitry
Password protected setup
NEMA4X (IP66) rated controller
100-250 VAC (50-60 Hz)
1 Amp, 24 Watts max. |
Catalogue
|
|
|
External Alarm Light & Horn
An external alarm light with combination audible horn is an electronic device designed to alert operators and other personnel both visually and audibly to a specific danger. |
Catalogue
|
|
|
4. Automatic Control Valves |
|
OV-1000 Omni-Valve
The new and improved Omni-Valve for automatic feed rate control.
Automatic feed control of Chlorine (Cl2), Sulfur Dioxide (SO2) & Ammonia gas (NH3) - Liquid feed control of Sodium Hypochlorite (NaOCl) and *others.
Elongated linear drive design for increased accuracy - Eliminates rotary motion for minimal wear
Maximum Capacity: 10,000 PPD (200 kg/h) Cl2
2 line x 20 character display.
Control Modes: Manual, Remote, Flow Pacing, Proportional, Residual, ORP, Compound Loop (PID), Step-Feed, Dual Input Feed Forward and Dual Set-Point
Modbus Communication (RS-485)
Two relay contact alarm outputs
Two standard 4-20 mA outputs
Ten point linearization process for accurate and repeatable control
Available as a special order item for pressure feed applications (20 PSI maximum).
*Consult factory for options. |
Catalogue
Wall Panel Catalogue
|
|
|
Omni Valve-110
Next Generation Automatic Valve for Feed Rate Control
Automatic feed of Chlorine gas, Sulfur Dioxide gas, Ammonia gas, Sodium Hypochlorite & other liquid chemicals.
Linear drive design eliminates rotary motion - means minimal wear.
Max Capacity: 6000 PPD (120 kg/h) Gas or 10 GPM Liquid Chemical Feed.
2 line x 20 character display.
Control Modes: Manual, Remote, Flow Pacing, Proportional, Residual, ORP,Compound Loop (PID), Step-Feed and Dual Input Feed Forward.
*Modbus Communication (RS-485)
Two relay contact alarm outputs
Two (2) standard 4-20 mA outputs.
Ten point linearization process for accurate control.
Includes delays, filters and threshold adjustment.
Available as a special order item for pressure feed applications (20 PSIG or less).
Password Protected Settings.
*MODBUS is only available in units with the new hardware that started shipping after April 2013. |
Catalogue
Wall Panel Catalogue
|
|
|
Control Valve-230
A Simple Valve for Automatic Proportional Feed Control
Compact design and simple proportional programming.
Automatic feed of Chlorine gas, Sulfur Dioxide gas, Ammonia gas, Sodium Hypochlorite & other liquid chemicals (vacuum systems).
Excellent accuracy and repeatability.
Control Modes: Manual and Automatic (Proportional / Flow Pacing).
Capacities up to 6000 PPD (120 kg/h) gas or 10 GPM liquid feed.
Linear drive design eliminates rotary motion -ensures minimal wear.
Ten point linearization process for accurate feed control.
2 line x 20 character display.
Contact alarm relay and (2) 4-20 mA outputs standard.
NEMA 4X Enclosure.
Available as a special order item for pressure feed applications (20 PSIG or less).
Password Protected Settings. |
Catalogue
Wall Panel Catalogue
|
|
|
|
|
|
|